Phillips Pump LLC


661 Lindley St. Bridgeport CT  06606          Phone: 203.576.6688          Fax: 203.576.0409


Home
Pump Sets
Day Tanks
Fuel Transfer Systems
Centrifugal Pumps
Positive Displacement Pumps
Fuel Oil Purify
Pump/Tank Controllers & Alarms
Float, Leak & Level Probes
Accessories
About Phillips
Contact Us
 
 
 
 
 
 
 
 
 
 
 
 

Double Wall Day Tanks With Pumps And Controls

Phillips Pump double wall (PDWT) day tanks provide a ready supply of oil or diesel fuel for boilers, diesel generators, or other stationary, engine-driven or burner-fired equipment.  With capacities ranging from 25 to 500 gallons, Phillips Pump day tanks may be selected for maximum fuel capacity for placement in a minimum amount of space.

Our PWDT series of double wall day tank/pump systems has an integral higher capacity outer chamber to protect against spills in event of leaks due to a high pressure rupture or internal damage to the inner tank.  Each day tank/pump system includes 2 GPM pump(s) as standard with pump / level controller, a mechanical gauge for visual level indication, a UL sized vent port, a 4" NPT inspection / emergency vent port, 2" NPT manual fill port, 1" NPT pump fill, engine supply, engine return, overflow, and drain ports.

All tanks are manufactured in accordance with a UL 142 label and meet NFPA 30 standards.  Each Phillips Pump day tank is constructed from 10 gauge steel, internally reinforced and seam welded to provide long lasting life in rugged industrial and commercial environments.

Each Day Tank / Pump System Includes:

  • Heavy gauge, seam welded, reinforced steel tank with heavy gauge steel channel support base with mounting holes
  • Mechanical tank gauge for visual level indication
  • Factory mounted 2 GPM positive displacement gear pumps with open drip-proof motors as standard for fuel oil supply and/or return (higher flow rates, TEFC or explosion proof motors available)
  • Corrosion-resistant internal epoxy coating
  • Complete array of fittings and connections (see double wall fitting schedule under storage tanks)
  • Engine supply and pump ports with supplied with drop tubes
  • Multi-level probe for pump on/off operation and low level or high level alarms
  • 135% outer chamber standard on double wall tanks
  • Day tank controller, tank top factory installed, with illuminated pump manual off automatic mode selector switches, power on, low and high level alarm indication lights, audible alarm, press to test and system reset push-buttons and alarm dry contact for interfacing to building management systems
  • Tank, pump and control options available to meet the specific requirements for each application
  • 115 VAC, single phase, 60 Hz, other volts and three phase systems are available

Day Tank / Pump System Combinations

PDWTS Series - Double wall day tank system with a single supply pump where the fuel can drain by gravity back to the main storage tank (suggested specification).

PDWTR Series - Double wall day tank system typically used for overflow tank situations where the fuel source is above the day tank.  System comes complete with a single return pump only (suggested specification).

PDWTSS Series - Double wall day tank system typically used in mission critical situations where supply must be maintained.  System comes complete with (2) supply pumps with automatic pump alternation and automatic lag pump start on low level alarm (suggested specification).

PDWTSR Series - Double wall typically used in day tank systems where the main storage tank is on the same level with the day tank when a single supply pump is required with a single return to drain tank in a high level alarm condition (suggested specification).

PDWTRR Series - Double wall day tank system typically use for overflow tank situations where the fuel source is above the day tank and a back up pump is required.  System comes complete with (2) return pumps, automatic return pump alternation with automatic lag return pump start on a high level alarm (suggested specification).

PDWTSSR Series - Double wall day tank system with duplex (2) supply and (1) return pump typically used in mission critical systems when fuel supply must be maintained and where the main storage tank is on the same level.  System comes complete with (2) supply pumps, with supply automatic pump alternation, automatic lag supply pump start on low level alarm and a single return to drain tank in a high level alarm situation (suggested specification).


Gallons

Double wall tank with (1) supply pump & controls

Double wall tank with (1) return pump & controls

Double wall tank with duplex (2) supply pumps & controls

Double wall tank with (1) supply & (1) return pump & controls

Double wall tank with duplex return pumps & controls

Double wall tank with duplex supply & (1) return pump & controls

25

PDWTS-25

PDWTR-25

PDWTSS-25

PDWTSR-25

PDWTRR-25

PDWTSSR-25

50

PDWTS-50

PDWTR-50

PDWTSS-50

PDWTSR-50

PDWTRR-50

PDWTSSR-50

60

PDWTS-60

PDWTR-60

PDWTSS-60

PDWTSR-60

PDWTRR-60

PDWTSSR-60

75

PDWTS-75

PDWTR-75

PDWTSS-75

PDWTSR-75

PDWTRR-75

PDWTSSR-75

100

PDWTS-100

PDWTR-100

PDWTSS-100

PDWTSR-100

PDWTRR-100

PDWTSSR-100

150

PDWTS-150

PDWTR-150

PDWTSS-150

PDWTSR-150

PDWTRR-150

PDWTSSR-150

200

PDWTS-200

PDWTR-200

PDWTSS-200

PDWTSR-200

PDWTRR-200

PDWTSSR-200

250

PDWTS-250

PDWTR-250

PDWTSS-250

PDWTSR-250

PDWTRR-250

PDWTSSR-250

275

PDWTS-275

PDWTR-275

PDWTSS-275

PDWTSR-275

PDWTRR-275

PDWTSSR-275

325

PDWTS-325

PDWTR-325

PDWTSS-325

PDWTSR-325

PDWTRR-325

PDWTSSR-325

400

PDWTS-400

PDWTR-400

PDWTSS-400

PDWTSR-400

PDWTRR-400

PDWTSSR-400

500

PDWTS-500

PDWTR-500

PDWTSS-500

PDWTSR-500

PDWTRR-500

PDWTSSR-500

Note: To delete the pump from single pump systems or a pump from dual pump systems, specify (1) option 1002.  To delete both pumps from dual pump systems specify option 1003.


Our Most Popular Options

Option

Description

1010

Auxiliary hand pump, rotary vane type, 10 GPM at 135 RPM

1015

Auxiliary hand pump, piston type, 20 GPM per 100 strokes

1025

Manual fuel fill cap, 2" lockable

1040

Wall mounting brackets (available on double wall tanks or single wall tanks without basin)

1050

Pipe stand adapters to raise tank above floor

1055

Simplex fuel strainer on supply pump inlet

1060

Duplex strainer with selector valve on supply pump inlet

1063

Vent cap, screened, for installation at outdoor vent termination

1064

Emergency vent, 4" NPT

1065

Drain valve with locking handle

1070

Priming tee and check valve assembly; factory assembled unit consisting of a plugged pump priming tee, a plugged fuel line priming tee and check valve

1080

Solenoid valve, normally closed to prevent loss of prime or tank flooding

1081

Solenoid valve, normally open, to shut down flow for additional protection in case of a high level alarm

1082

Flow control manifolds, factory assembled units consisting of: i) one normally closed solenoid valve to direct flow for multi-tank applications and to prevent loss of prime or tank flooding, ii) one normally open solenoid valve to shut down flow and provide additional protection in case of a high level tank condition, and iii) two isolation valves and manual bypass tee with ball valve

1087

Manual shut off ball valves, bronze body

1088

Manual shut off ball valves, fire rated

1090

Foot valve, 1" NPT on engine supply drop tube to prevent loss of prime

1092

Fusible link valve, lever type (includes wire coil and fuse link)

1093

Fusible link valve, arm type

1094

Check valve, bronze, swing type

1095

Pump internal relief valve

1100

Pressure gauge, liquid filled, on pump discharge

1101

Compound vacuum/pressure gauge on suction side of pump

1103

Flow indictor, ball type

1130

Extra engine supply or engine return pipe connections; includes drop tubes (please specify location and quantity)

1132

Extra piping connections (please specify location and quantity)

1135

Oversized piping connections

1180

Weatherproof modification

1191

Rupture basin leak sensor (available for double wall tanks or single wall tanks with basin)

1197

Fuel in vent detection sensor

1211

Sight glass with steel guard and valves

1285

Single level float level probe, Buna N float with brass stem and locking rings, single level (note: typically for high level auxiliary indication)

1490

a) 4 GPM supply or return pump with, 1/3 HP, 1725 RPM motor

 

b) 7 GPM supply or return pump with, 1/2 HP, 1725 RPM motor

 

c) 10 GPM supply or return pump with, 3/4 HP, 1725 RPM motor

 

d) 15 GPM supply or return pump with, 1 HP, 1725 RPM motor

 

e) 23 GPM supply or return pump with, 1 1/2 HP, 1725 RPM motor


 
 
Home | Contact Us | Feedback | About Us